fcps-24s8 manual
FCPS-24S8⁚ System Overview
The FCPS-24S8 is an 8-amp remote power supply and battery charger. It’s compact, cost-effective, and offers ADA-compliant strobe synchronization. This unit charges lead-acid batteries from 7.0 AH to 18.0 AH.
Power Supply Capabilities
The FCPS-24S8 provides a reliable power source for fire alarm systems. Its 8-amp capacity ensures sufficient power for a wide range of devices. The power supply features an integral supervised battery charger, specifically designed for lead-acid batteries. This ensures continuous operation even during power outages. The unit is compatible with both 12 and 24-volt fire alarm control panels (FACPs), offering flexibility in system integration. It can operate efficiently with a 120VAC input, making it suitable for various electrical environments. The FCPS-24S8’s short-term maximum current output is 8.0 amps for one hour, providing ample power during peak demand. Its compact design allows for easy installation in various locations.
Battery Charging Specifications
The FCPS-24S8 incorporates a built-in, supervised battery charger exclusively for lead-acid batteries. It’s designed to charge batteries ranging from 7.0 Amp-hours (Ah) to 18.0 Ah, providing flexibility for various system configurations. The charging process is carefully managed to ensure optimal battery life and performance. Regular monitoring of the charging process is facilitated by the supervised nature of the charger, enabling early detection of any potential issues. This ensures reliable backup power during power outages. The charger is integrated seamlessly into the compact design of the FCPS-24S8, simplifying installation and maintenance. Specific charging parameters may be found in the detailed technical specifications section of the complete manual.
FCPS-24S8⁚ Installation
Proper installation ensures optimal performance and safety. Consult the detailed instructions within the manual for step-by-step guidance and wiring diagrams.
Connecting to a Fire Alarm Control Panel
Connecting the FCPS-24S8 to your fire alarm control panel (FACP) is crucial for system functionality. This process involves carefully following the wiring diagrams and instructions provided in the manual. Ensure proper connection to avoid malfunctions or damage to the equipment. Incorrect wiring can lead to system failures or safety hazards. Always double-check all connections before powering on the system. Consult a qualified electrician if unsure about any aspect of the installation process. Proper grounding is essential for safety and reliable operation. Reference the specific connection points detailed in the FCPS-24S8 manual for your particular FACP model. Failure to follow these instructions may void any warranties.
Wiring and Connections
The FCPS-24S8’s wiring and connections require careful attention to detail. Use appropriately sized wires for all connections to ensure proper current flow and prevent overheating. Follow the color-coded wiring diagram provided in the manual precisely. Secure all connections firmly to avoid loose contacts, which may lead to intermittent operation or system failure. Ensure that all connections are made to the correct terminals. Improper wiring can pose a significant safety risk. Grounding is critical for both safety and reliable system performance; verify the ground connection is secure and properly installed. Consult a qualified electrician if you are unsure about any aspect of the wiring or connections. Always disconnect power before making any wiring changes.
FCPS-24S8⁚ Dip Switch Settings
Configure strobe synchronization and other programmable features using the dip switches. Consult the detailed instructions and tables within this manual for proper settings.
Strobe Synchronization Options
The FCPS-24S8 offers selectable strobe synchronization options to ensure compatibility with various notification appliance manufacturers. These options are configured using the dip switches. Available synchronization types include⁚ No synchronization (steady 24V output), System Sensor, Gentex, and Wheelock. Proper selection is crucial for reliable operation. Incorrect settings might lead to improper strobe behavior or malfunction. Refer to the dip switch table for specific settings for each strobe type. Always verify the compatibility of your chosen strobe with the selected synchronization mode before installation.
Other Programmable Features
Beyond strobe synchronization, the FCPS-24S8 may offer additional programmable features controlled via its dip switches. Consult the detailed dip switch settings table within the complete manual for a comprehensive list and explanations of each setting. These features may include options for fault monitoring, output current limiting, or other functionalities to optimize system performance and safety. Incorrect configuration could affect system operation. Therefore, carefully review all available settings and choose those appropriate for your specific fire alarm system needs. Always refer to the manufacturer’s documentation for detailed instructions and safety precautions.
FCPS-24S8⁚ Technical Specifications
This section details the FCPS-24S8’s electrical characteristics, including input voltage and current requirements, and output current capacity. Refer to the full manual for precise values.
Input Voltage and Current
The FCPS-24S8 power supply operates with a 120VAC, 60Hz input voltage. Precise current draw specifications are detailed in the complete FCPS-24S8 manual. This information is crucial for proper installation and to ensure compatibility with your existing electrical system. Failure to meet these requirements could result in malfunction or damage to the unit. Always verify the input voltage and current at your installation site match the specifications outlined in the full manual before connecting the FCPS-24S8. Consult a qualified electrician if you have any concerns or uncertainties about the electrical compatibility of your installation environment with the FCPS-24S8’s specifications.
Output Current and Amperage
The FCPS-24S8 provides a maximum output current of 8.0 amps. This is a crucial specification for determining the number of devices it can power. The system’s capacity to handle this amperage is vital for reliable operation. Exceeding the maximum output could lead to system failure or damage to connected equipment. Refer to the complete FCPS-24S8 manual for detailed load calculations and compatibility information to ensure your devices are within the safe operating parameters. Careful planning and adherence to these specifications are essential for a successful and safe installation of the FCPS-24S8 power supply.
FCPS-24S8⁚ Certifications and Compliance
The FCPS-24S8 meets stringent safety and performance standards, including UL, ULC, CSFM, and MEA certifications, ensuring reliable and safe operation.
UL, ULC, CSFM, and MEA Compliance
The FCPS-24S8 power supply boasts comprehensive certifications, demonstrating its adherence to rigorous safety and performance standards. UL (Underwriters Laboratories) listing signifies its compliance with North American safety requirements. ULC (Underwriters Laboratories of Canada) certification ensures it meets Canadian safety regulations. CSFM (California State Fire Marshal) approval confirms its suitability for use in California. Finally, MEA (Municipal Equipment Approval) indicates its acceptance by various municipal authorities, ensuring broad applicability and peace of mind for installers and users. These certifications underscore the FCPS-24S8’s reliability and suitability for diverse fire alarm system installations across various jurisdictions.
Safety Standards Adherence
The FCPS-24S8’s design prioritizes safety, adhering to stringent industry standards. Its certifications (UL, ULC, CSFM, and MEA) validate its compliance with nationally and internationally recognized safety regulations. These certifications ensure the power supply operates reliably and safely within specified parameters, minimizing risks associated with electrical hazards and ensuring the integrity of the fire alarm system. Regular maintenance, as outlined in the maintenance section of this manual, further contributes to the long-term safe operation of the FCPS-24S8, helping to protect lives and property. Proper installation and adherence to all instructions are crucial for maintaining these safety standards.
Related Fire-Lite Products
Consider complementary Fire-Lite products like the MMF-300-10 monitor module and the D355PL smoke detector housing for a complete fire safety system.
MMF-300-10 Monitor Module
The Fire-Lite MMF-300-10 Ten-Input Monitor Module complements the FCPS-24S8, providing comprehensive monitoring capabilities. This module allows for the connection and supervision of up to ten different circuits or devices within a fire alarm system. Its integration with the FCPS-24S8 power supply ensures reliable operation and efficient power management for the connected devices. The MMF-300-10 offers enhanced system monitoring and diagnostics, providing valuable information about the status of various components within the fire alarm system. This contributes to improved system reliability and faster response times in emergency situations. Its compact design makes it easy to install and integrate into existing systems, minimizing disruption and maximizing efficiency.
D355PL Smoke Detector Housing
The Fire-Lite D355PL Intelligent Non-Relay Photoelectric Low Flow Smoke Detector Housing provides a robust and reliable enclosure for smoke detectors. Designed for seamless integration with the FCPS-24S8 power supply, it ensures consistent power delivery to the installed smoke detector. The D355PL housing is constructed from high-quality materials to withstand harsh environmental conditions, ensuring long-term performance and reliability. Its intelligent design allows for easy installation and maintenance, minimizing downtime. This housing is compatible with various types of smoke detectors, offering flexibility in system design and upgrades. The D355PL’s compatibility with the FCPS-24S8 enhances the overall efficiency and performance of your fire alarm system.
Troubleshooting and Maintenance
Consult the manual for common issues and solutions. Regular maintenance, including inspections, ensures optimal system performance and safety.
Common Issues and Solutions
Address power supply problems by checking connections and input voltage. If the battery isn’t charging, inspect the charger and battery itself for faults. Low output current might indicate a faulty internal component or overloaded system. Consult the troubleshooting section of the manual for detailed guidance on diagnosing and resolving these and other potential issues. Remember to always disconnect power before performing any maintenance or troubleshooting steps. Incorrect dip switch settings can cause unexpected behavior; verify they align with the desired configuration. For advanced troubleshooting or persistent problems, contact technical support for assistance.
Regular Maintenance Procedures
Regularly inspect the FCPS-24S8 for any signs of damage, loose connections, or corrosion. Clean the unit’s exterior using a damp cloth. Ensure proper ventilation around the unit to prevent overheating. Periodically check the battery voltage and condition; replace if necessary. Monitor the output current to ensure it’s within the specified range. Refer to the manufacturer’s recommendations for the recommended frequency of these checks and any specific maintenance procedures. Keeping the unit clean and properly connected will help maintain optimal performance and longevity. Proper maintenance ensures reliable operation and extends the life of your power supply.